MVR FW 250 series

MVR FW 250 series

You have chosen to download our software.

Within a few seconds, you will receive an email containing a download link.

Having trouble using the software? Please contact support@deif.com. 

Best regards, 

DEIF A/S

The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software

2.5.7.1-245

New features 

  • Hardware: Support for T option card (1 x mA output - 4 x mA input).
  • Function: DIF (Idx>) [87T] and GMAG: Individual setting groups (SGS2). 
  • Generator module: Nominal scaling manual mode. 
  • VRG1 (Vreg) [90]: Parallel Voltage Regulator.
  • GMAG: Excitation current to mA Out channel selection. 
  • HMI: Alarm view colour selector. 
  • HMI: Arabic language to start screen. 
  • HMI: Chinese font support for objects. 
  • Communication: Ethernet GOOSE storm protection parameter. 
  • Communication: Double Ethernet PRP ports parameter.
  • Communication: Support for PTP power profiles and VLAN-tagged frames. 
  • Communication: Scaled analogue inputs to IEC 104. 
  • Communication: CTS2 to IEC 61850 mapping. 
  • Communication: URX1 and URX2 [21X] conditions to IEC 61850. 
  • Communication: VHZ1 (2) conditions to IEC 61850. 
  • Communication: Capacitor Protection Module Conditions COL1/2 and CNU1 to legacy protocols. 
  • Communication: U3/U4 frequency to IEC 61850. 
  • Communication: Switch positions added to GOOSE.
  • Communication: GOOSE analogue values added to HMI and programmable stages.

Changes

  • Pole Slip [78]: Function improvements.
  • Synchro check [25]: Added LL/DL/LD/DD mode, ability to select line or bus as reference, additional signals. 
  • HMI: Default mimic updated to light theme. 
  • HMI: Several menu item and text adjustments, addition of function ANSI codes. 
  • Fault register: "Fault values register" and "Measurement value recorder" renamed to “Fault register”.

 

Corrections

  • Synchro check [25]: SYN2 and SYN3 force status. 
  • Current transformer supervision: Current transformer supervision functionality was not working if delay was not zero. 
  • Directional overcurrent (Idir>) [67]: Protection blocking set start to zero. 
  • Current unbalance (I2>) [46]: Adjustments to IDMT tripping time calculation. 
  • Voltage regulation (Vreg) [90]: Scaling curve positions were not working. 
  • Frequency measurement: Min/Max tracking frequency allowed limits were not working. 
  • Frequent start FSP (N>) [66]: Frequent start stage was not working correctly.
  • Logic: >= comparator was also activated on negative values. 
  • Objects: Default user level changed from operator to configurator. 
  • HMI: Push buttons were in undefined state after reboot if set to toggle mode. 
  • HMI: Reset to factory defaults will now reboot HMI and clear mimics and fault registers correctly. 
  • HMI: Custom event description display on event list. 
  • HMI: Vector and trip time characteristics.
  • HMI: Measurement bar scaling. 
  • Disturbance recorder: Recording failed when device name was more than 28 characters. 
  • Disturbance recorder: Issues saving digital outputs to "REC Digital channels" - selection. 
  • Underexcitation protection (X<) [40]: RX circle radius was renamed from diameter to radius to reflect intended functionality.
  • Frequency protection f>/< [81O/81U]: fmeas/fset value was always zero. 
  • Harmonics measurement: Harmonic measurement percentage values were "Infinite". 
  • NOC1 (I>) [50/51]: Fault register was not showing fault phases correctly. 
  • Communication/ IEC 61850: Energy measurement demand values not updating. 
  • Communication/ IEC 61850: UCP1 (IUC>) [46C]: UIC Testout event inconsistency. 
  • Communication/ IEC 61850: SOTF: SOF1GGIO1 condition check not updating.

2.5.7.1-245

28/03/2025

New features 

  • Hardware: Support for T option card (1 x mA output - 4 x mA input).
  • Function: DIF (Idx>) [87T] and GMAG: Individual setting groups (SGS2). 
  • Generator module: Nominal scaling manual mode. 
  • VRG1 (Vreg) [90]: Parallel Voltage Regulator.
  • GMAG: Excitation current to mA Out channel selection. 
  • HMI: Alarm view colour selector. 
  • HMI: Arabic language to start screen. 
  • HMI: Chinese font support for objects. 
  • Communication: Ethernet GOOSE storm protection parameter. 
  • Communication: Double Ethernet PRP ports parameter.
  • Communication: Support for PTP power profiles and VLAN-tagged frames. 
  • Communication: Scaled analogue inputs to IEC 104. 
  • Communication: CTS2 to IEC 61850 mapping. 
  • Communication: URX1 and URX2 [21X] conditions to IEC 61850. 
  • Communication: VHZ1 (2) conditions to IEC 61850. 
  • Communication: Capacitor Protection Module Conditions COL1/2 and CNU1 to legacy protocols. 
  • Communication: U3/U4 frequency to IEC 61850. 
  • Communication: Switch positions added to GOOSE.
  • Communication: GOOSE analogue values added to HMI and programmable stages.

Changes

  • Pole Slip [78]: Function improvements.
  • Synchro check [25]: Added LL/DL/LD/DD mode, ability to select line or bus as reference, additional signals. 
  • HMI: Default mimic updated to light theme. 
  • HMI: Several menu item and text adjustments, addition of function ANSI codes. 
  • Fault register: "Fault values register" and "Measurement value recorder" renamed to “Fault register”.

 

Corrections

  • Synchro check [25]: SYN2 and SYN3 force status. 
  • Current transformer supervision: Current transformer supervision functionality was not working if delay was not zero. 
  • Directional overcurrent (Idir>) [67]: Protection blocking set start to zero. 
  • Current unbalance (I2>) [46]: Adjustments to IDMT tripping time calculation. 
  • Voltage regulation (Vreg) [90]: Scaling curve positions were not working. 
  • Frequency measurement: Min/Max tracking frequency allowed limits were not working. 
  • Frequent start FSP (N>) [66]: Frequent start stage was not working correctly.
  • Logic: >= comparator was also activated on negative values. 
  • Objects: Default user level changed from operator to configurator. 
  • HMI: Push buttons were in undefined state after reboot if set to toggle mode. 
  • HMI: Reset to factory defaults will now reboot HMI and clear mimics and fault registers correctly. 
  • HMI: Custom event description display on event list. 
  • HMI: Vector and trip time characteristics.
  • HMI: Measurement bar scaling. 
  • Disturbance recorder: Recording failed when device name was more than 28 characters. 
  • Disturbance recorder: Issues saving digital outputs to "REC Digital channels" - selection. 
  • Underexcitation protection (X<) [40]: RX circle radius was renamed from diameter to radius to reflect intended functionality.
  • Frequency protection f>/< [81O/81U]: fmeas/fset value was always zero. 
  • Harmonics measurement: Harmonic measurement percentage values were "Infinite". 
  • NOC1 (I>) [50/51]: Fault register was not showing fault phases correctly. 
  • Communication/ IEC 61850: Energy measurement demand values not updating. 
  • Communication/ IEC 61850: UCP1 (IUC>) [46C]: UIC Testout event inconsistency. 
  • Communication/ IEC 61850: SOTF: SOF1GGIO1 condition check not updating.

On this page, you can download software updates for your product(s) and help yourself to various utility tools and add-ons that will assist you in setting up, detecting faults and configuring your product(s).

Please be advised that not all of our products can be updated by the user. Nor do all of our products come with a utility tool. Consequently, the list on this page cannot be considered an overview of our product programme.

DEIF will register your download along with the used e-mail address for the purpose of sending out information on future updates, if requested.

DEIF cannot be made responsible for any consequences of failed product updates or use of utility tools. Nor can DEIF A/S be made responsible for consequences of changes in behaviour of products due to a software upgrade. It is always the responsibility of the user to ensure correct set-up and configuration before commissioning. Please study the version log of the software before updating the product.

Licence agreement for software downloaded from www.deif.com

Downloaded software remains the property of DEIF. The software may not be distributed for commercial purposes, changed or reused in full or in part or sold to any third parties.

The latest versions for full functionality

As always, we recommend that you install our offered improvements to fully utilise your DEIF product.

All improved software can be downloaded at your convenience at www.deif.com under “Software”.

Should you have any questions or experience problems finding the relevant software for your product, please feel free to call DEIF A/S at +45 96149614 or your relevant local DEIF office. Alternatively, we are always ready to assist you, if you send an e-mail to support@deif.com.