iE 350 Marine application SW (Protection & Paralleling)
iE 350 Marine application SW (Protection & Paralleling)
You have chosen to download our software.
Within a few seconds, you will receive an email containing a download link.
Having trouble using the software? Please contact support@deif.com.
Best regards,
DEIF A/S
The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software
2.0.9.0
2.0.9.0 based on 2.0.8.1
New features
- Three pump logic routines can now be set up to control the pumping of a substance.
- Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.
- All configuration dependent values are now possible to use in the flexible Modbus.
Changes
- Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.
- Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350.
- Added write permission for "Priorities" when the controller is in emulation.
- EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control".
- EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation.
Corrections
- Fixed issue where changes made in the UI were not registered.
- Fixed issue where the "IO configuration" menu would show empty slots.
- Fixed issue where tree-structure menu groups could not be collapsed using touch.
- Fixed issue where configuring a Modbus value to "true" made the value "255" instead of "1".
- Fixed issue where measurements from multiple ECUs were not shown in the UI for e.g. configuring alarms.
- Fixed issue where the display user could not clear DM2 logs.
- Fixed issue where the iE controller could not start without MIO module.
- Fixed issue with missing alarm icons.
- Fixed issue where the user could enter parameter values outside of the valid range.
- Fixed checksum and counter for VP70.
- Fixed issue where removing the network cable would activate system NOK, IO service error and "temperature too high" alarms.
- Fixed issue where CODESYS user management files were not included in backup/restore.
- Fixed issue where linked outputs in CODESYS were hidden in IO configuration.
2.0.9.0 |
04/05/2025 |
2.0.9.0 based on 2.0.8.1New features
Changes
Corrections
|
2.0.8.1 |
10/02/2025 |
Corrections
Changes
|
2.0.8.0 |
17/01/2025 |
2.0.8.0 based on 2.0.4.1 New features
Changes
Corrections
|
2.0.4.1 |
12/07/2024 |
Initial release of the iE 350 Marine. The iE 350 Marine, our next-generation controller product line for the maritime segment, features an award-winning design ensuring intuitive and efficient operation. The iE 350 Marine exceeds IACS UR E27 cybersecurity regulations, providing robust protection against cyber threats. Engineered for superior performance and reliability, it meets the rigorous demands of modern maritime applications. This software package is intended to serve the CORE level functionality. Minimum required version of PICUS: 1.0.22.0 New features
Corrections
|